TERASAKI ELCB RCCB 10MA 16A 20A 25A 2POLE 4POLES TECS
RCDs for which tripping is ensured for residual sinusoidal alternating currents; whether suddenly applied or slowly arising.
Apple Shopping Event
Hurry and get discounts on all Apple devices up to 20%
Sale_coupon_15
RM92.70 – RM109.00
-
Warranty included
-
User menu available for download
Payment Methods:

-
Pick up from any Exerlon Power HQ branch
To pick up today
Free
-
Pick up from any Exerlon Power Penang branch
To pick up today
Free
-
Pick up from any Exerlon Power Johor branch
To pick up today
Free
-
Pick up from any Exerlon Power Ipoh branch
To pick up today
Free
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
Charges will be applied
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
Free
-
Warranty included
-
User menu available for download
Product Description
TRIP CHARACTERISTICS
FAULT CURRENT SENSITIVITY
The RCD employs the current balance principle which involves the supply conductors to the load (phase and neutral) wound onto a common transformer core to form the primary windings. Under healthy conditions, the current in the phase conductor is equal to the current in the neutral and the vector sum of the current is zero.
RESIDUAL TRIPPING CURRENTS
Semi-conductor devices are extensively integrated in equipments in industries, commerce and in our homes. They can be found in control panels to computers to toys. As equipments are fed from the mains electrical supply; in the event of an earth fault, the presence of semi-conductors may result in the normal AC waveform being replaced by a non-sinusoidal fault current. In some cases, the waveform may be rectified. These waveforms are said to contain a pulsating DC component which can either partially desensitize a standard type AC RCD. International standards IEC 1008 (RCCBs) and IEC 1009 (RCBOs) divide RCDs into two performance classes:
Type AC
RCDs for which tripping is ensured for residual sinusoidal alternating currents; whether suddenly applied or
slowly arising.
In the event of an earth fault, an amount of current will flow to earth, creating an out of balance situation in the transformer assembly. This out of balance detected by the secondary winding of the transformer will activate the trip mechanism at a pre-determined level. Single phase and neutral or three phases and neutral units (suitable for both 3 wire and 4 wire systems) are available, the latter being suitable for balanced or unbalanced 3 phase loads. The RCD tripping mechanism will operate at a residual current of between 50%-100% of its rated tripping current. (Sensitivity)
10mA Suitable for use in special applications where additional protection against contact is essential
high levels of earth leakage are experienced.
Specification
Customer Reviews
Reviews
Clear filtersThere are no reviews yet.
Related Products
ABB auto recloser elcb F2C-ARI-30 TM15/12 RCCB ELCB + Auto / Remote Reclosing elcb
In stock
ABB MCB 4.5kA-10kA 6A-63A 1P/2P/3P Miniature Circuit Breaker
In stock
ABB RCCB ELCB RCD sirim 40A 63A 100A 30ma 100ma 300ma earth leakage breaker
In stock
CHINT MCCB 25-250A 25ka 35ka NXM-125S NXM-160S NXM-250S 25A 32A 40A 50A 63A 80A 100A 125A 160A 200A 225A 250A 3pole
In stock
LS MCB 6KA 6A 10A 16A 20A 32A 40A 63A BK63N MINITURE CIRCUIT BREAKER 1POLE 2POLE 3POLE
In stock
SCHNEIDER Circuit Breaker EasyPact CVS400N 4 Poles, 400A, 50kA LV540319
In stock
Weight | 6.039 kg |
---|---|
Dimensions | 30 × 16 × 24.4 cm |
Brand |
Schneider |
Range of Product |
EasyPact |
Product or Component Type |
Circuit Breaker |
Device Short Name |
CVS400N |
Poles |
4 Poles |
Current Rating |
400A |
Utilisation Category |
Category A |
Breaking Capacity |
50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 |
Function Available |
Overload Protection ,Short-Circuit Protection |
Mechanical Durability |
15000 cycles conforming to IEC 60947-2 |
Electrical Durability |
6000 cycles 415 V In conforming to IEC 60947-2 |
Mounting Mode |
Fixed |
Reviews
Clear filtersThere are no reviews yet.