-
Warranty included

TERASAKI MCCB accessories shunt trip uvt handle under voltage trip
RM80.00 – RM275.00

TERASAKI ELCB RCCB 30MA 100MA 300MA 40A 63A 100A 2POLE 4POLES
RM55.00 – RM240.00
TERASAKI ELCB RCCB 10MA 16A 20A 25A 2POLE 4POLES TECS
SKU:
3956228604
RCDs for which tripping is ensured for residual sinusoidal alternating currents; whether suddenly applied or slowly arising.
Apple Shopping Event
Hurry and get discounts on all Apple devices up to 20%
Sale_coupon_15
RM92.70 – RM109.00
0
People watching this product now!
Payment Methods:

-
Pick up from any Exerlon Power HQ branch
To pick up today
Free
-
Pick up from any Exerlon Power Penang branch
To pick up today
Free
-
Pick up from any Exerlon Power Johor branch
To pick up today
Free
-
Pick up from any Exerlon Power Ipoh branch
To pick up today
Free
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
Charges will be applied
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
Free
-
Warranty included
-
User menu available for download
Product Description
TRIP CHARACTERISTICS
FAULT CURRENT SENSITIVITY
The RCD employs the current balance principle which involves the supply conductors to the load (phase and neutral) wound onto a common transformer core to form the primary windings. Under healthy conditions, the current in the phase conductor is equal to the current in the neutral and the vector sum of the current is zero.
RESIDUAL TRIPPING CURRENTS
Semi-conductor devices are extensively integrated in equipments in industries, commerce and in our homes. They can be found in control panels to computers to toys. As equipments are fed from the mains electrical supply; in the event of an earth fault, the presence of semi-conductors may result in the normal AC waveform being replaced by a non-sinusoidal fault current. In some cases, the waveform may be rectified. These waveforms are said to contain a pulsating DC component which can either partially desensitize a standard type AC RCD. International standards IEC 1008 (RCCBs) and IEC 1009 (RCBOs) divide RCDs into two performance classes:
Type AC
RCDs for which tripping is ensured for residual sinusoidal alternating currents; whether suddenly applied or
slowly arising.
In the event of an earth fault, an amount of current will flow to earth, creating an out of balance situation in the transformer assembly. This out of balance detected by the secondary winding of the transformer will activate the trip mechanism at a pre-determined level. Single phase and neutral or three phases and neutral units (suitable for both 3 wire and 4 wire systems) are available, the latter being suitable for balanced or unbalanced 3 phase loads. The RCD tripping mechanism will operate at a residual current of between 50%-100% of its rated tripping current. (Sensitivity)
10mA Suitable for use in special applications where additional protection against contact is essential
high levels of earth leakage are experienced.
Rated 0 out of 5
0 reviews
Rated 5 out of 5
0
Rated 4 out of 5
0
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0
Be the first to review “TERASAKI ELCB RCCB 10MA 16A 20A 25A 2POLE 4POLES TECS” Cancel reply
You must be logged in to post a review.
Specification
Customer Reviews
Rated 0 out of 5
0 reviews
Rated 5 out of 5
0
Rated 4 out of 5
0
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0
Reviews
Clear filtersThere are no reviews yet.
Be the first to review “TERASAKI ELCB RCCB 10MA 16A 20A 25A 2POLE 4POLES TECS” Cancel reply
You must be logged in to post a review.
Related Products
ABB MCCB 50kA XT2S160 3poles 32A 40A 63A 100A XT1N160 36KA
Rated 0 out of 5
In stock
RM288.00 – RM460.00
Select options
This product has multiple variants. The options may be chosen on the product page
SKU:
11247240274
CHINT NL1-63 / NL1-100 RCCB / ELCB Earth Leakage Circuit Breaker, 40A / 63A / 100A (30mA / 100mA / 300mA)
Rated 0 out of 5
In stock
RM49.60 – RM255.00
Select options
This product has multiple variants. The options may be chosen on the product page
SKU:
CHINT E●●/● 0.●●
CHINT RCBO/RCCB 25A, 1P+N, 10mA (Water Heater Earth Leakage Protection), NBH8LE / NL1-63-25A
Rated 0 out of 5
In stock
RM78.60
Select options
This product has multiple variants. The options may be chosen on the product page
SKU:
CHINT E25/2 0.01 / CHINT RCBO25010-NBH8LE
HAGER ELCB RCCB 30MA 100MA 300MA 40A 63A 100A 2POLE 4POLES
Rated 0 out of 5
In stock
RM82.00 – RM570.00
Select options
This product has multiple variants. The options may be chosen on the product page
SKU:
6658291705
L&T 20-1250A MCCB 10-65kA 2Poles/3Poles/4Poles
Rated 0 out of 5
In stock
RM92.00 – RM4,681.50
Select options
This product has multiple variants. The options may be chosen on the product page
SKU:
8075970218
model |
DU100H ,DY125U ,DN0-100C ,DN0-100D ,DZ1-160D ,DZ1-160N ,DN1-250N ,DN1-250D ,DN2-250N ,DN2-150D ,DN3-400D ,DN3-630N ,DN4-1250N |
---|---|
poles |
2 ,3 ,4 |
currentRating |
20A ,25A ,30A ,40A ,50A ,63A ,80A ,100A ,125A ,160A ,200A ,250A ,320A ,400A ,500A ,630A ,800A ,1000A ,1250A |
breakingCapacity |
10kA ,36kA ,50kA ,65kA |
SCHNEIDER RCCB Acti iLD 4 Poles 100A 30/100/300mA Type AC, A9R11491 / A9R12491 / A9R14491
Rated 0 out of 5
In stock
RM319.00 – RM419.00
Select options
This product has multiple variants. The options may be chosen on the product page
SKU:
SCHNEIDER A9R●●491
Poles |
4 Poles |
---|---|
Current Rating |
100A |
Sensitivity |
100mA ,300mA ,30mA |
Brand |
Schneider |
Range of Product |
Acti9 iID |
Product or Component Type |
Residual Current Circuit Breaker (RCCB) |
Device Short Name |
iLD |
Class Type |
Type AC |
Mounting Mode |
Clip-On ,DIN Rail |
Colour |
WHITE |
Electrical Durability |
AC-1: 10000 cycles |
Mechanical Durability |
20000 cycles |
Reviews
Clear filtersThere are no reviews yet.