
TERASAKI ELCB RCCB 30MA 100MA 300MA 40A 63A 100A 2POLE 4POLES
RCDs for which tripping is ensured for residual sinusoidal alternating currents; whether suddenly applied or slowly arising.
Apple Shopping Event
Hurry and get discounts on all Apple devices up to 20%
Sale_coupon_15
RM55.00 – RM240.00
-
Warranty included
-
User menu available for download
Payment Methods:

-
Pick up from any Exerlon Power HQ branch
To pick up today
Free
-
Pick up from any Exerlon Power Penang branch
To pick up today
Free
-
Pick up from any Exerlon Power Johor branch
To pick up today
Free
-
Pick up from any Exerlon Power Ipoh branch
To pick up today
Free
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
Charges will be applied
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
Free
-
Warranty included
-
User menu available for download
Product Description
TRIP CHARACTERISTICS
FAULT CURRENT SENSITIVITY
The RCD employs the current balance principle which involves
the supply conductors to the load (phase and neutral) wound onto
a common transformer core to form the primary windings. Under
healthy conditions, the current in the phase conductor is equal to
the current in the neutral and the vector sum of the current is zero.
RESIDUAL TRIPPING CURRENTS
Semi-conductor devices are extensively integrated in equipments in industries, commerce and in our homes.
They can be found in control panels to computers to toys.
As equipments are fed from the mains electrical supply; in the event of an earth fault, the presence of semi-conductors may result in the
normal AC waveform being replaced by a non-sinusoidal fault current. In some cases, the waveform may be rectified. These waveforms are
said to contain a pulsating DC component which can either partially desensitize a standard type AC RCD.
International standards IEC 1008 (RCCBs) and IEC 1009 (RCBOs) divide RCDs into two performance classes:
Type AC
RCDs for which tripping is ensured for residual sinusoidal alternating currents; whether suddenly applied or
slowly arising.
In the event of an earth fault, an amount of current will flow to earth,
creating an out of balance situation in the transformer assembly.
This out of balance detected by the secondary winding of the
transformer will activate the trip mechanism at a pre-determined
level. Single phase and neutral or three phases and neutral units
(suitable for both 3 wire and 4 wire systems) are available, the latter
being suitable for balanced or unbalanced 3 phase loads.
The RCD tripping mechanism will operate at a residual current of
between 50%-100% of its rated tripping current. (Sensitivity)
10mA Suitable for use in special applications where additional protection against contact is essential
30mA Tripping current to provide additional protection against direct contact shock
100mA Suitable for use against direct contact shock or where protection is guard against fire hazards etc.
300mA Suitable for use in large installations where equipment protection are main considerations and
high levels of earth leakage are experienced.
Specification
Customer Reviews
Reviews
Clear filtersThere are no reviews yet.
Related Products
ABB MCB 4.5kA-10kA 6A-63A 1P/2P/3P Miniature Circuit Breaker
In stock
CHINT RCBO/RCCB 25A, 1P+N, 10mA (Water Heater Earth Leakage Protection), NBH8LE / NL1-63-25A
In stock
EPS 6kA 1P / 2P / 3P Miniature Circuit Breaker, MCB, 6A / 10A / 16A / 20A / 32A / 40A
In stock
L&T LARSEN & TOUBRO LT RCCB ELCB RCD 40A 63A 100A 30ma 100ma 300ma earth leakage breaker
In stock
L&T MCCB Accessories shunt trip uvt handle under voltage trip
In stock
SCHNEIDER Circuit Breaker ComPact NSX400N 4 Poles, 400A, 50kA C40N42D400
In stock
Weight | 7.308 kg |
---|---|
Dimensions | 29 × 20.5 × 15 cm |
Brand |
Schneider |
Range of Product |
ComPacT New Generation |
Product or Component Type |
Circuit Breaker |
Device Short Name |
NSX400N |
Poles |
4 Poles |
Utilisation Category |
Category A |
Breaking Capacity |
50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 |
Trip Unit |
MicroLogic 2.3 |
Mounting Mode |
Fixed |
Mechanical Durability |
15000 cycles conforming to IEC 60947-2 |
Electrical Durability |
12000 cycles at 440 V In/2 ,3000 cycles at 690 V In ,6000 cycles at 440 V In ,6000 cycles at 690 V In/2 |
Function Available |
I : for instantaneous short-circuit protection ,L : for overload protection (long time) ,So : for short time short-circuit protection with fixed delay |
Reviews
Clear filtersThere are no reviews yet.