-
Warranty included
“Schneider RCCB with Overcurrent Protection (RCBO) Acti9 iC60H 10mA, 1P + Ns, 20A, 10mA, A type, 10kA A9D10820” has been added to your cart. View cart
CHINT RCBO/RCCB 25A, 1P+N, 10mA (Water Heater Earth Leakage Protection), NBH8LE / NL1-63-25A
SKU:
CHINT E25/2 0.01 / CHINT RCBO25010-NBH8LE
Protect people against indirect contacts and additional protection against direct contacts.
Apple Shopping Event
Hurry and get discounts on all Apple devices up to 20%
Sale_coupon_15
RM87.35
0
People watching this product now!
Payment Methods:
-
Pick up from any Exerlon Power HQ branch
To pick up today
Free
-
Pick up from any Exerlon Power Penang branch
To pick up today
Free
-
Pick up from any Exerlon Power Johor branch
To pick up today
Free
-
Pick up from any Exerlon Power Ipoh branch
To pick up today
Free
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
Charges will be applied
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
Free
-
Warranty included
-
User menu available for download
For NL1-63-25A RCCB:
Function:
– Control electric circuits.
– Protect people against indirect contacts and additional protection against direct contacts.
– Protect installations against fire hazard due to insulation faults.
– Residual current circuit breakers are used in housing, tertiary sector and industry.
Selection:
– Detectable wave form
AC class:
Tripping is ensured for slowly increasing sinusoidal AC residual currents.
A class:
Tripping is ensured for sinusoidal AC residual currents and for pulsed DC residual currents, whether applied suddenly or increasing slowly.
S, G/SI class:
Tripping is ensured not only for sinusoidal AC residual currents but also for pulsed DC residual currents whether applied suddenly or increasing slowly. S, G/SI type with filters against spurious tripping caused by harmonics and transient surges.
With the impact of 8/20us surge 3000A, this high immunity
RCCB will still be in stable status.
For NBH8LE RCBO:
Function
– Personnel and fire protection
– Cable and line protection against overload and short-circuits.
Selection
– I∆n = 10mA, 30mA: additional protection in the case of direct contact.
– C curve (5-10 In) protection and control of the circuits against overloads and short-circuits, protection for resistive and inductive loads with low inrush current.
AC class
Tripping is ensured for sinusoidal, alternating currents, whether they be quickly applied or slowly increase.
Rated 0 out of 5
0 reviews
Rated 5 out of 5
0
Rated 4 out of 5
0
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0
Be the first to review “CHINT RCBO/RCCB 25A, 1P+N, 10mA (Water Heater Earth Leakage Protection), NBH8LE / NL1-63-25A” Cancel reply
You must be logged in to post a review.
Specification
Overview
| Current Rating |
25A |
|---|---|
| Sensitivity |
10mA |
| Breaking Capacity |
6kA |
General
| Brand |
CHINT |
|---|---|
| Product or Component Type |
Residual current breaker with overcurrent protection (RCBO) ,Residual Current Circuit Breaker (RCCB) |
Customer Reviews
Rated 0 out of 5
0 reviews
Rated 5 out of 5
0
Rated 4 out of 5
0
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0
Reviews
Clear filtersThere are no reviews yet.
Be the first to review “CHINT RCBO/RCCB 25A, 1P+N, 10mA (Water Heater Earth Leakage Protection), NBH8LE / NL1-63-25A” Cancel reply
You must be logged in to post a review.
Related Products
[BUNDLE] ABB Auto Recloser ELCB F3C-AR230 / F3C-AR230 D + RCCB / ELCB
Rated 0 out of 5
In stock
RM1,000.00 – RM1,111.15
Select options
This product has multiple variants. The options may be chosen on the product page
SKU:
ABB E●●/● ●.●● + ABB F3C-AR230
CHINT Next Series NXC Contactor NXC-09 / NXC-12 / NXC -18 / NXC-25 / NXC-32 / NXC-40 / NXC-50 / NXC-65 / NXC-85 / NXC-100
Rated 0 out of 5
In stock
RM30.00 – RM205.60
Select options
This product has multiple variants. The options may be chosen on the product page
SKU:
CHINT NXC-●●-11 240
| Model |
NXC-09 ,NXC-12 ,NXC-18 ,NXC-25 ,NXC-32 ,NXC-40 ,NXC-50 ,NXC-65 ,NXC-85 ,NXC-100 ,NXC-120 ,NXC-160 ,NXC-185 ,NXC-225 ,NXC-330 ,NXC-400 ,NXC-500 ,NXC-630 |
|---|---|
| Voltage Rating |
240 VAC |
| Coil Voltage |
240 VAC |
| Aux. Contact Composition |
1 NO + 1 NC |
| Brand |
CHINT |
| Product or Component Type |
Contactor |
| Range of Product |
NXC Series |
CHINT Next Series Thermal Overload Relay (TOR) NXR-25 / NXR-38 / NXR-100 / NXR-200
Rated 0 out of 5
In stock
RM31.30 – RM377.80
Select options
This product has multiple variants. The options may be chosen on the product page
SKU:
CHINT NXR-●●-●●●
| Model |
NXR-100 ,NXR-200 ,NXR-25 ,NXR-38 |
|---|---|
| Current Rating |
0.1-0.16A ,0.16-0.25A ,0.25-0.4A ,0.4-0.63A ,0.63-1A ,1-1.6A ,1.6-2.5A ,100-200A ,12-18A ,17-25A ,2.5-4A ,23-32A ,30-38A ,30-40A ,37-50A ,4-6A ,48-65A ,5.5-8A ,55-70A ,63-80A ,7-10A ,80-100A ,80-160A ,9-13A |
| Brand |
CHINT |
| Function Available |
Manual & Automatic Reset ,Phase Loss Protection ,Stop Button ,Temperature Compensation ,Test Button ,Trip Indication |
| Aux. Contact Composition |
1 NO + 1 NC |
| Product or Component Type |
Differential Thermal Overload Relay |
Duval RCCB Single and Three Phase RCCB with Auto Reset System
Rated 0 out of 5
In stock
RM928.15 – RM1,333.35
Select options
This product has multiple variants. The options may be chosen on the product page
SKU:
DUVAL DAR330●AI E●●/0.●●
| Poles |
2 Poles ,4 Poles |
|---|---|
| Current Rating |
100A ,40A ,63A |
| Sensitivity |
100mA ,300mA ,30mA |
| Brand |
DUVAL |
| Device Short Name |
DAR330 |
| Product or Component Type |
Earth-Leakage / Residual Current Circuit Breaker (ELCB / RCCB) with Recloser |
| Voltage Rating |
240 VAC ,400…415 VAC |
| Breaking Capacity |
10kA (High Short Circuit Current) ,3kA (Surge Current) |
| Class Type |
Type AI (For AC and DC Leakage) |
| Function Available |
Built-In Trip Counter ,Nuisance tripping available ,Operating mechanism is QUICK-Made and Quick-Break and Trip-Free type mechanism with de-ion arc interrupters ,Protection for AC and DC leakage |
Schneider RCCB with Overcurrent Protection (RCBO) Acti9 iC60H 10mA, 1P + Ns, 20A, 10mA, A type, 10kA A9D10820
Rated 5.00 out of 5
In stock
RM220.00
SKU:
SCHNEIDER A9D10820
| Weight | 0.211 kg |
|---|---|
| Dimensions | 1.8 × 9.5 × 7.5 cm |
| Poles |
1P+N |
| Current Rating |
20A |
| Sensitivity |
10mA |
| Brand |
Schneider |
| Range of Product |
Acti9 |
| Product or Component Type |
Residual current breaker with overcurrent protection (RCBO) |
| Device Short Name |
iC60H RCBO |
| Curve Code |
C Curve |
| Breaking Capacity |
10kA Icn at 230/240 VAC 50/60 Hz |
| Mechanical Durability |
20000 cycles |
| Electrical Durability |
5000 cycles conforming to IEC 60947-2 |
TERASAKI ELCB RCCB 10MA 16A 20A 25A 2POLE 4POLES TECS
Rated 0 out of 5
In stock
RM103.00 – RM121.15
Select options
This product has multiple variants. The options may be chosen on the product page
SKU:
3956228604
Reviews
Clear filtersThere are no reviews yet.